Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38227804

RESUMO

AIMS: Although guidelines for the management of atrial fibrillation (AF) are regularly published, many controversial issues remain, limiting their implementation. We aim to describe current clinical practice among European Heart Rhythm Association (EHRA) community according to last guidelines. METHODS AND RESULTS: A 30 multiple-choice questionnaire covering the most controversial topics related to AF management was distributed through the EHRA Research Network, National Societies, and social media between January and February 2023. One hundred and eighty-one physicians responded the survey, 61% from university hospitals. Atrial fibrillation screening in high-risk patients is regularly performed by 57%. Only 42% has access to at least one programme aiming at diagnosing/managing comorbidities and lifestyle modifications, with marked heterogeneity between countries. Direct oral anticoagulants are the preferred antithrombotic (97%). Rhythm control is the preferred strategy in most AF phenotypes: symptomatic vs. asymptomatic paroxysmal AF (97% vs. 77%), low vs. high risk for recurrence persistent AF (90% vs. 72%), and permanent AF (20%). I-C drugs and amiodarone are preferred while dronedarone and sotalol barely used. Ablation is the first-line therapy for symptomatic paroxysmal AF (69%) and persistent AF with markers of atrial disease (57%) and is performed independently of symptoms by 15%. In persistent AF, 68% performs only pulmonary vein isolation and 32% also additional lesions. CONCLUSION: There is marked heterogeneity in AF management and limited accordance to last guidelines in the EHRA community. Most of the discrepancies are related to the main controversial issues, such as those related to AF screening, management of comorbidities, pharmacological treatment, and ablation strategy.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Comorbidade , Inquéritos e Questionários , Sotalol , Anticoagulantes/uso terapêutico , Resultado do Tratamento
3.
Circ Arrhythm Electrophysiol ; 16(9): e011914, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37577822

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)|max. Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different (P<0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Eletroporação , Terapia com Eletroporação
4.
Front Cardiovasc Med ; 10: 1162197, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37346283

RESUMO

Background: Circumferential ablation around the ipsilateral pulmonary veins (PVs) is the standard strategy for atrial fibrillation ablation. The present study seeks to assess which regions of the standard ablation circumference are the main contributors to the venoatrial electrical connection. Methods: A total of 41 patients were included under a specific atrial fibrillation ablation protocol in which the anterior and posterior segments of the standard circumference, between the equatorial line of the superior and the inferior ipsilateral PVs, were ablated first. If PV isolation was not achieved, ablation was extended superiorly or inferiorly, on the basis of the earliest atrial activation recorded during pacing from inside the PV. Complete PV isolation and the length of the areas not requiring ablation (ANRA) at the time of electrical isolation were evaluated. Results: Ablation of the anterior and posterior segments of the standard circumference led to the isolation of 77% left-PV pairs and 51% right-PV pairs (p = 0,015). A superior extension was required in 23% left-PV pairs and in 46% right-PV pairs, while an inferior extension was required only in 10% left-PV pairs and in 11% right-PV pairs. PV isolation was achieved before completing the standard ablation circumference in 97% left-PV pairs and in 94% right-PV pairs, with a median ANRA of 36.9 (IQR: 30.9-42.1) mm in the left PVs [16.0 (IQR: 12.0-19.0) mm superior and 18.8 (IQR: 16.1-24.9) mm inferior, p < 0.01] and 36.9 (IQR: 30.2-41.0) mm in the right PVs [15.1 (IQR: 10.7-19.1) mm superior and 20.6 (IQR: 16.9-23.3) mm inferior, p < 0.01]. Conclusions: The myocardial fibers along the anterior and posterior regions of the standard ablation circumference are the main contributors to the electrical connection between the pulmonary veins and the left atrium. Ablation of these regions results in PV isolation in the majority of patients.

5.
Front Cardiovasc Med ; 10: 1110165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37051067

RESUMO

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

8.
Front Cardiovasc Med ; 9: 1000027, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36330001

RESUMO

Background: Low-voltage-substrate (LVS)-guided ablation for persistent atrial fibrillation (AF) has been described either in sinus rhythm (SR) or AF. Prolonged fractionated potentials (PFPs) may represent arrhythmogenic slow conduction substrate and potentially co-localize with LVS. We assess the spatial correlation of PFP identified in AF (PFP-AF) to those mapped in SR (PFP-SR). We further report the relationship between LVS and PFPs when mapped in AF or SR. Materials and methods: Thirty-eight patients with ablation naïve persistent AF underwent left atrial (LA) high-density mapping in AF and SR prior to catheter ablation. Areas presenting PFP-AF and PFP-SR were annotated during mapping on the LA geometry. Low-voltage areas (LVA) were quantified using a bipolar threshold of 0.5 mV during both AF and SR mapping. Concordance of fractionated potentials (CFP) (defined as the presence of PFPs in both rhythms within a radius of 6 mm) was quantified. Spatial distribution and correlation of PFP and CFP with LVA were assessed. The predictors for CFP were determined. Results: PFPs displayed low voltages both during AF (median 0.30 mV (Q1-Q3: 0.20-0.50 mV) and SR (median 0.35 mV (Q1-Q3: 0.20-0.56 mV). The duration of PFP-SR was measured at 61 ms (Q1-Q3: 51-76 ms). During SR, most PFP-SRs (89.4 and 97.2%) were located within LVA (<0.5 mV and <1.0 mV, respectively). Areas presenting PFP occurred more frequently in AF than in SR (median: 9.5 vs. 8.0, p = 0.005). Both PFP-AF and PFP-SR were predominantly located at anterior LA (>40%), followed by posterior LA (>20%) and septal LA (>15%). The extent of LVA < 0.5 mV was more extensive in AF (median: 25.2% of LA surface, Q1-Q3:16.6-50.5%) than in SR (median: 12.3%, Q1-Q3: 4.7-29.4%, p = 0.001). CFP in both rhythms occurred in 80% of PFP-SR and 59% of PFP-AF (p = 0.008). Notably, CFP was positively correlated to the extent of LVA in SR (p = 0.004), but not with LVA in AF (p = 0.226). Additionally, the extent of LVA < 0.5 mV in SR was the only significant predictor for CFP, with an optimal threshold of 16% predicting high (>80%) fractionation concordance in AF and SR. Conclusion: Substrate mapping in SR vs. AF reveals smaller areas of low voltage and fewer sites with PFP. PFP-SR are located within low-voltage areas in SR. There is a high degree of spatial agreement (80%) between PFP-AF and PFP-SR in patients with moderate LVA in SR (>16% of LA surface). These findings should be considered when substrate-based ablation strategies are applied in patients with the left atrial low-voltage substrate with recurrent persistent AF.

9.
Front Cardiovasc Med ; 9: 1101152, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36712269

RESUMO

Background: Progressive atrial fibrotic remodeling has been reported to be associated with atrial cardiomyopathy (ACM) and the transition from paroxysmal to persistent atrial fibrillation (AF). We sought to identify the anatomical/structural and electrophysiological factors involved in atrial remodeling that promote AF persistency. Methods: Consecutive patients with paroxysmal (n = 134) or persistent (n = 136) AF who presented for their first AF ablation procedure were included. Patients underwent left atrial (LA) high-definition mapping (1,835 ± 421 sites/map) during sinus rhythm (SR) and were randomized to training and validation sets for model development and evaluation. A total of 62 parameters from both electro-anatomical mapping and non-invasive baseline data were extracted encompassing four main categories: (1) LA size, (2) extent of low-voltage-substrate (LVS), (3) LA voltages and (4) bi-atrial conduction time as identified by the duration of amplified P-wave (APWD) in a digital 12-lead-ECG. Least absolute shrinkage and selection operator (LASSO) and logistic regression were performed to identify the factors that are most relevant to AF persistency in each category alone and all categories combined. The performance of the developed models for diagnosis of AF persistency was validated regarding discrimination, calibration and clinical usefulness. In addition, HATCH score and C2HEST score were also evaluated for their performance in identification of AF persistency. Results: In training and validation sets, APWD (threshold 151 ms), LA volume (LAV, threshold 94 mL), bipolar LVS area < 1.0 mV (threshold 4.55 cm2) and LA global mean voltage (GMV, threshold 1.66 mV) were identified as best determinants for AF persistency in the respective category. Moreover, APWD (AUC 0.851 and 0.801) and LA volume (AUC 0.788 and 0.741) achieved better discrimination between AF types than LVS extent (AUC 0.783 and 0.682) and GMV (AUC 0.751 and 0.707). The integrated model (combining APWD and LAV) yielded the best discrimination performance between AF types (AUC 0.876 in training set and 0.830 in validation set). In contrast, HATCH score and C2HEST score only achieved AUC < 0.60 in identifying individuals with persistent AF in current study. Conclusion: Among 62 electro-anatomical parameters, we identified APWD, LA volume, LVS extent, and mean LA voltage as the four determinant electrophysiological and structural factors that are most relevant for AF persistency. Notably, the combination of APWD with LA volume enabled discrimination between paroxysmal and persistent AF with high accuracy, emphasizing their importance as underlying substrate of persistent AF.

10.
Heart Rhythm O2 ; 3(6Part A): 699-705, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589920

RESUMO

Background: The role of catheter tip shape on the safety and efficacy of radiofrequency (RF) ablation has been overlooked, although differences have been observed in clinical and research fields. Objective: The purpose of this study was to analyze the role of electrode tip shape in RF ablation using a computational model. Methods: We simulated 108 RF ablations through a realistic 3-dimensional computational model considering 2 clinically used, open-irrigated catheters (spherical and cylindrical tip), varying contact force (CF), blood flow, and irrigation. Lesions are defined by the 50°C isotherm contour and evaluated by means of width, depth, depth at maximum width, and volume. Ablations are deemed as safe, critical (tissue temperature >90°C), and pop (tissue temperature >100°C). Results: Tissue-electrode contact is less for the spherical tip at low CF but the relationship is inverted at high CF. At low CF, the cylindrical tip generates deeper and wider lesions and a 4-fold larger volume. With increasing CF, the lesions generated by the spherical tip become comparable to those generated by the cylindrical tip. The 2 tips feature different safety profiles: CF and power are the main determinants of pops for the spherical tip; power is the main factor for the cylindrical tip; and CF has a marginal effect. The cylindrical tip is more prone to pop generation at higher powers. Saline irrigation and blood flow effect do not depend on tip shape. Conclusion: Tip shape determines the performance of ablation catheters and has a major impact on their safety profile. The cylindrical tip shows more predictable behavior in a wide range of CF values.

11.
Clin Res Cardiol ; 111(9): 1018-1027, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34854991

RESUMO

AIMS: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care. METHODS: In this multicenter, prospective study, a new risk stratification model termed AF-SCORE was derived in 220 patients undergoing high-density left-atrial(LA) voltage-mapping to quantify FAM. AF-SCORE was validated for FAM in an external mapping-validation cohort (n = 220) and for success following pulmonary vein isolation (PVI)-only (without adjunctive left- or right atrial ablations) in an external outcome-validation cohort (n = 518). RESULTS: FAM was rare in patients < 60 years (5.4%), but increased with ageing and affected 40.4% (59/146) of patients ≥ 60 years. Sex and AF-phenotype had additional predictive value in older patients and remained associated with FAM in multivariate models (odds ratio [OR] 6.194, p < 0.0001 for ≥ 60 years; OR 2.863, p < 0.0001 for female sex; OR 41.309, p < 0.0001 for AF-persistency). Additional clinical or diagnostic variables did not improve the model. AF-SCORE (+ 1 point for age ≥ 60 years and additional points for female sex [+ 1] and AF-persistency [+ 2]) showed good discrimination to detect FAM (c-statistic 0.792) and predicted arrhythmia-freedom following PVI (74.3%, 54.7% and 45.5% for AF-SCORE ≤ 2, 3 and 4, respectively, and hazard ratio [HR] 1.994 for AF-SCORE = 3 and HR 2.866 for AF-SCORE = 4, p < 0.001). CONCLUSIONS: Age, sex and AF-phenotype are the main determinants for the development of FAM. A low AF-SCORE ≤ 2 is found in paroxysmal AF-patients of any age and younger patients with persistent AF irrespective of sex, and associated with favorable outcomes of PVI-only. Freedom from arrhythmia remains unsatisfactory with AF-SCORE ≥ 3 as found in older patients, particularly females, with persistent AF, and future studies investigating adjunctive atrial ablations to PVI-only should focus on these groups of patients.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Fibrose , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 32(6): 1584-1593, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33772926

RESUMO

BACKGROUND: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI). METHODS: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.5 mV) was considered as significant at 2 cm2  or above. Preprocedural clinical electrocardiogram and echocardiographic data were assessed to identify predictors of LA-LVS. The role of the identified LA-LVS markers in predicting 1-year arrhythmia freedom after PVI was assessed in 245 patients. RESULTS: Significant LA-LVS was identified in 123 (42%) patients. The amplified sinus P-wave duration (APWD) best predicted LA-LVS, with a 148-ms value providing the best-balanced sensitivity (0.81) and specificity (0.88). An APWD over 160 ms was associated with LA-LVS in 96% of patients, whereas an APWD under 145 ms in 15%. Remaining gray zones improved their accuracy by introduction of systolic pulmonary artery pressure (sPAP) of 35 mmHg or above, age, and sex. According to COX regression, the risk of arrhythmia recurrence 12 months following PVI was twofold and threefold higher in patients with APWD 145-160 and over 160 ms, compared to APWD under 145 ms. Integration of pulmonary hypertension further improved the outcome prediction in the intermediate APWD group: Patients with APWD 145-160 ms and normal sPAP had similar outcome than patients with APWD under 145 ms (hazard ratio [HR] 1.62, p = .14), whereas high sPAP implied worse outcome (HR 2.56, p < .001). CONCLUSIONS: The APWD identifies LA-LVS and risk for arrhythmia recurrence after PVI. Our prediction model becomes optimized by means of integration of the pulmonary artery pressure.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
14.
J Arrhythm ; 37(1): 259-260, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33664915

RESUMO

We describe through a clinical case some of the challenges we can face when remotely monitoring a patient with two devices. The case describes a patient with two leadless pacemaker in which data transmission by remote monitoring has been achieved.

15.
Front Med Technol ; 3: 747609, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047958

RESUMO

Background: High-power short-duration (HPSD) recently emerged as a new approach to radiofrequency (RF) catheter ablation. However, basic and clinical data supporting its effectiveness and safety is still scarce. Objective: We aim to characterize HPSD with an advanced virtual model, able to assess lesion dimensions and complications in multiple conditions and compare it to standard protocols. Methods: We evaluate, on both atrium and ventricle, three HPSD protocols (70 W/8 s, 80 W/6 s, and 90 W/4 s) through a realistic 3D computational model of power-controlled RF ablation, varying catheter tip design (spherical/cylindrical), contact force (CF), blood flow, and saline irrigation. Lesions are defined by the 50°C isotherm contour. Ablations are deemed safe or complicated by pop (tissue temperature >97°C) or charring (blood temperature >80°C). We compared HPSD with standards protocols (30-40 W/30 s). We analyzed the effect of a second HPSD application. Results: We simulated 432 applications. Most (79%) associated a complication, especially in the atrium. The three HPSD protocols performed similarly in the atrium, while 90 W/4 s appeared the safest in the ventricle. Low irrigation rate led frequently to charring (72%). High-power short-duration lesions were 40-60% shallower and smaller in volume compared to standards, although featuring similar width. A second HPSD application increased lesions to a size comparable to standards. Conclusion: High-power short-duration lesions are smaller in volume and more superficial than standards but comparable in width, which can be advantageous in the atrium. A second application can produce lesions similar to standards in a shorter time. Despite its narrow safety margin, HPSD seems a valuable new clinical approach.

16.
JACC Clin Electrophysiol ; 6(5): 523-532, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32439036

RESUMO

OBJECTIVES: The aim of this study was to describe a mapping approach for ablation of complex atrial re-entrant tachycardias (ARTs) in which high-density activation maps are transformed into low-density activation maps displaying only the active part of the tachycardia circuit. BACKGROUND: High-density activation maps during complex ARTs are challenging to interpret because they include the activation patterns of active and passive circuits. Entrainment mapping provides the identification of the active tachycardia circuit. However, current electroanatomic mapping systems are not capable of color-coding the information obtained from entrainment maneuvers. METHODS: Seventeen consecutive patients with atypical atrial flutter were included. A high-density activation map was acquired during index tachycardia. Subsequently, entrainment maneuvers were performed to generate a low-density activation map in which only the activation of the atria directly involved in the flutter circuit was displayed. RESULTS: Of all patients included, 82% were men, and their mean age was 62 ± 7 years. Structural heart disease was present in 59%, and 53% had undergone prior left atrial ablation procedures. Low-density activation maps were successfully generated from an average of 14 ± 3 entrainment points. Twenty circuits (95%) were identified in the left atrium and 1 (5%) in the right atrium. Ablation guided by low-density mapping successfully terminated all ARTs in 267 ± 353 s of radiofrequency application. CONCLUSIONS: Low-density mapping based on entrainment maneuvers provides a precise delineation of the active circuit during complex ARTs and resulted in successful arrhythmia termination. This approach can be easily incorporated into clinical practice.


Assuntos
Flutter Atrial , Ablação por Cateter , Taquicardia Supraventricular , Flutter Atrial/cirurgia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia , Taquicardia Supraventricular/cirurgia
17.
Rev. esp. cardiol. (Ed. impr.) ; 73(4): 307-312, abr. 2020. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-195611

RESUMO

INTRODUCCIÓN Y OBJETIVOS: El marcapasos transcatéter Micra presenta una alta efectividad y una tasa de complicaciones más baja que los marcapasos convencionales. Sin embargo, se desconoce su beneficio en la población más anciana (≥ 90 años). El objetivo de este estudio es evaluar la efectividad y la seguridad de Micra en pacientes de edad ≥ 90 años. MÉTODOS: Estudio observacional prospectivo con pacientes consecutivos mayores de 70 años a los que se implantó un marcapasos Micra, divididos en 2 grupos de edad: ≥ 90 y <90 años. RESULTADOS: El Micra se implantó en 129 pacientes, 41 tenían 90 o más años y 88, menos de 90. El implante fue exitoso en 40 pacientes (97,6%) de edad ≥ 90 años y en 87 (98,9%) menores de 90 (p = 0,58). Fueron necesarias 2 o menos reposiciones en el 97,5 y el 91,9% de los pacientes respectivamente (p = 0,32). Los tiempos de procedimiento (26,1±11,6 frente a 30,3±14,2min; p = 0,11) y de fluoroscopia (6,4±4,7 frente a 7,2±4,9min; p = 0,41) fueron similares en ambos grupos. Hubo 3 complicaciones mayores (2,3%), todas en el grupo menor de 90 años: 1 perforación cardiaca, 1 hematoma femoral y 1 seudoaneurisma femoral. Un total de 13 pacientes de edad ≥ 90 años (31,7%) y 16 de los menores de 90 (18,2%) murieron durante unos seguimientos medios de 230±233 y 394±285 días respectivamente. No hubo muertes relacionadas con el dispositivo. No se observaron infección, dislocación o migración de Micra. El rendimiento eléctrico fue óptimo en el seguimiento. CONCLUSIONES: El marcapasos sin cables Micra parece efectivo y seguro en pacientes mayores de 90 años. Podría considerarse una alternativa razonable a la estimulación transvenosa convencional en esta población


INTRODUCTION AND OBJECTIVES: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years. METHODS: We present a prospective observational study with consecutive patients aged >70 years who underwent implantation of a Micra pacemaker system. Patients were divided into 2 groups: ≥ 90 and<90 years. RESULTS: The Micra system was implanted in 129 patients, of whom 41 were aged ≥ 90 years and 88<90 years. The device was successfully implanted in 40 (97.6%) patients ≥ 90 years and in 87 (98.9%) patients<90 years (P=.58). An adequate position was achieved with need for ≤ 2 repositions in 97.5% and 91.9% of patients, respectively (P=.32). Procedure time (26.1 ±11.6 vs 30.3 ±14.2minutes; P=.11) and fluoroscopy time (6.4 ±4.7 vs 7.2 ±4.9minutes; P=0.41) were similar in the 2 groups. There were 3 major complications (2.3%), all in the group aged<90 years: 1 cardiac perforation, 1 femoral hematoma, and 1 femoral pseudoaneurysm. Thirteen patients aged ≥ 90 years (31.7%) and 16 patients aged <90 years (18.2%) died during a mean follow-up of 230±233 days and 394±285 days, respectively. There were no device-related deaths. No infection, dislocation or migration of Micra were observed. The electrical performance was optimal at follow-up. CONCLUSIONS: The Micra leadless pacing system seems to be safe and effective in patients older than 90 years. It may be considered a reasonable alternative to conventional transvenous pacing in this population


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Bradicardia/terapia , Marca-Passo Artificial , Registros , Nó Sinoatrial/fisiologia , Bradicardia/fisiopatologia , Desenho de Equipamento , Estudos Prospectivos , Resultado do Tratamento
18.
Heart Rhythm ; 17(7): 1084-1091, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32113896

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) carries an increased risk of sudden death due to ventricular arrhythmias (VAs). The implantable cardioverter-defibrillator (ICD) is a well-established therapy for treatment of VA. Monomorphic ventricular tachycardias (MVTs) are frequent in HCM patients and suitable for antitachycardia pacing (ATP) termination. OBJECTIVE: The purpose of this study was to describe ventricular tachycardia (VT) characteristics in a population of HCM patients with ICD and to study the effectiveness and safety of ATP for MVT. METHODS: Data were obtained from the multicenter prospective observational UMBRELLA trial, which included all patients with HCM and ICD followed by the CareLink Monitoring System. All episodes of VA were collected and analyzed. ATP effectiveness and safety were described, and factors related to ATP effectiveness were studied with generalized estimating equation (GEE) models. RESULTS: Among 251 patients followed for 47 months, 67 (26.7%) were implanted as secondary prevention. Fifty-six patients presented 326 episodes of VA (286 [87%] MVT). Mean cycle length was 312 ± 64 ms. Among 264 MVTs that received ICD therapy, 202 (76.5%) were ATP terminated. The first ATP burst was effective in 169 episodes (68.4%), and overall effectiveness of the first or second ATP burst was 73.8%. Multivariate GEE-adjusted analysis showed 2 variables related to ATP effectiveness: programming fast VT zone On vs Off (odds ratio [OR] 2.4; 95% confidence interval [CI] 1.5-5.2; P = .03) and programming ≥2 ATP bursts vs 1 burst only (OR 1.6; 95% CI 1.2-3.4; P = .04; and OR 2.9; 95% CI 1.8-6.3; P = .02; respectively). CONCLUSION: MVT is the predominant VA in HCM patients with ICD. ATP is highly effective in terminating the majority of MVTs, and its proved effectiveness should guide device selection and programming in order to avoid unnecessary high-energy shocks.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Prevenção Secundária/métodos , Choque Cardiogênico/prevenção & controle , Taquicardia Ventricular/terapia , Cardiomiopatia Hipertrófica/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Cardiogênico/etiologia , Taquicardia Ventricular/complicações , Resultado do Tratamento
19.
Rev Esp Cardiol (Engl Ed) ; 73(4): 307-312, 2020 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31395499

RESUMO

INTRODUCTION AND OBJECTIVES: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years. METHODS: We present a prospective observational study with consecutive patients aged >70 years who underwent implantation of a Micra pacemaker system. Patients were divided into 2 groups: ≥ 90 and<90 years. RESULTS: The Micra system was implanted in 129 patients, of whom 41 were aged ≥ 90 years and 88<90 years. The device was successfully implanted in 40 (97.6%) patients ≥ 90 years and in 87 (98.9%) patients<90 years (P=.58). An adequate position was achieved with need for ≤ 2 repositions in 97.5% and 91.9% of patients, respectively (P=.32). Procedure time (26.1 ±11.6 vs 30.3 ±14.2minutes; P=.11) and fluoroscopy time (6.4 ±4.7 vs 7.2 ±4.9minutes; P=0.41) were similar in the 2 groups. There were 3 major complications (2.3%), all in the group aged<90 years: 1 cardiac perforation, 1 femoral hematoma, and 1 femoral pseudoaneurysm. Thirteen patients aged ≥ 90 years (31.7%) and 16 patients aged <90 years (18.2%) died during a mean follow-up of 230±233 days and 394±285 days, respectively. There were no device-related deaths. No infection, dislocation or migration of Micra were observed. The electrical performance was optimal at follow-up. CONCLUSIONS: The Micra leadless pacing system seems to be safe and effective in patients older than 90 years. It may be considered a reasonable alternative to conventional transvenous pacing in this population.


Assuntos
Bradicardia/terapia , Marca-Passo Artificial , Sistema de Registros , Nó Sinoatrial/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Bradicardia/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
20.
Europace ; 22(2): 240-249, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31782781

RESUMO

AIMS: Presence of arrhythmogenic left atrial (LA) low-voltage substrate (LVS) is associated with reduced arthythmia freedom rates following pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). We hypothesized that LA-LVS modifies amplified sinus-P-wave (APW) characteristics, enabling identification of patients at risk for arrhythmia recurrences following PVI. METHODS AND RESULTS: Ninety-five patients with persistent AF underwent high-density (>1200 sites) voltage mapping in sinus rhythm. Left atrial low-voltage substrate (<0.5 and <1.0 mV) was quantified in a 10-segment LA model. Amplified sinus-P-wave-morphology and -duration were evaluated using digitized 12-lead electrocardiograms (40-80 mm/mV, 100-200 mm/s). 12-months arrhythmia freedom following circumferential PVI was assessed in 139 patients with persistent AF. Left atrial low-voltage substrate was most frequently (84%) found at the anteroseptal LA. Characteristic changes of APW were related to the localization and extent of LA-LVS. At an early stage, LA-LVS predominantly located to the LA-anteroseptum and was associated with APW-prolongation (≥150 ms). More extensive LA-LVS involved larger areas of LA-anteroseptum, leading to morphological changes of APW (biphasic positive-negative P-waves in inferior leads). Severe LA-LVS involved the LA-anteroseptum, roof and posterior LA, but spared the inferior LA, lateral LA, and LA appendage. In this advanced stage, widespread LVS at the posterior LA abolished the negative portion of P-wave in the inferior leads. The delayed activation of the lateral LA and LA appendage produced the late positive deflections in the anterolateral leads, resulting in the "late-terminal P"-pattern. Structured analysis of APW-duration and -morphology stratified patients to their individual extent of LA-LVS (Grade 1: mean LA-LVS 4.9 cm2 at <1.0 mV; Grade 2: 28.6 cm2; Grade 3: 42.3 cm2; P < 0.01). The diagnostic value of APW-duration for identification of LA-LVS was significantly superior to standard P-wave-amplification (c-statistic 0.945 vs. 0.647). Arrhythmia freedom following PVI differed significantly between APW-predicted grades of LA-LVS-severity [hazard ratio (HR) 2.38, 95% confidence interval (CI) 1.18-4.83; P = 0.015 for Grade 1 vs. Grade 2; HR 1.79, 95% CI 1.00-3.21, P = 0.049 for Grade 2 vs. Grade 3). Arrhythmia freedom 12 months after PVI was 77%, 53%, and 33% in Grades 1, 2 and 3, respectively. CONCLUSION: Localization and extent of LA-LVS modifies APW-morphology and -duration. Analysis of APW allows accurate prediction of LA-LVS and enables rapid and non-invasive estimation of arrhythmia freedom following PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Liberdade , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...